EVALUATING THE ACCURACY OF MASTER CASTS OF COMPLETE DENTURES PREPARED USING A NEW SIMPLIFIED BEADING AND BOXING PROCEDURE FOR ELASTOMERIC IMPRESSIONS
DOI:
https://doi.org/10.4238/fem0gt81Keywords:
complete denture; elastomeric impression; master cast; beading; boxing; plaster–pumice; prosthodonticsAbstract
Background: The accuracy of a master cast depends not only on the impression material and tray, but also on how the impression is supported and poured. Conventional wax boxing is difficult with elastomeric impressions because wax does not reliably adhere to their surfaces. A simplified plaster–pumice approach may provide a practical alternative while preserving the peripheral anatomy recorded in the impression. Objective: To evaluate the accuracy of master casts produced from elastomeric complete-denture impressions using a new simplified beading and boxing procedure and an inexpensive, clinically applicable grading system. Methods: This descriptive cross-sectional study was conducted in the Department of Prosthodontics, Liaquat University of Medical and Health Sciences, from 4 October 2022 to 4 April 2023. Ninety-six patients aged 45–75 years requiring a maxillary or mandibular complete denture were selected through consecutive sampling. Secondary elastomeric impressions were supported with a 1:1 plaster–pumice mixture, trimmed to establish the desired land area, boxed with wax, and poured with Type III dental stone. Casts were assessed using a predefined four-grade system based on cast thickness, land dimensions, vestibular depth, border extension, repositioning indices, surface finish, and dimensional deviation. Grades A and B were considered acceptable; grades C and D were considered compromised. Results: The mean age of participants was 54.28 ± 6.26 years; 43 (44.8%) were male and 53 (55.2%) were female. Grade A, B, C, and D casts accounted for 44 (45.8%), 23 (24.0%), 20 (20.8%), and 9 (9.4%) cases, respectively. Overall, 67 of 96 casts (69.8%; 95% CI: 60.0–78.1%) were classified as acceptable, whereas 29 (30.2%) were classified as compromised. Acceptable accuracy did not differ significantly according to age group (p = 0.275) or sex (p = 0.652). Conclusion: The new simplified plaster–pumice beading and boxing procedure produced acceptable master casts in approximately seven out of ten cases. It uses readily available laboratory materials, does not require a separating medium, and offers a practical method for preserving impression borders during cast fabrication. Prospective comparative studies with objective dimensional measurements and operator calibration are needed before the technique can be recommended as a standard protocol.
Downloads
Published
Issue
Section
License

This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.

